JEOL JMS-Q1600GC UltraQuad™ SQ-Zeta Gas Chromatograph Quadrupole Mass Spectrometer Model:JMS-Q1600GC UltraQuad™ SQ-Zeta

The new JMS-Q1600GC UltraQuad™ SQ-Zeta of JEOL is our 6th generation high-end Gas Chromatograph Quadrupole Mass Spectrometer (GC-QMS) based on JEOL's 50 years of MS technologies and experience.From quantitative applications such as environmental samples, water quality control and agrochemicals, to qualitative applications such as materials and aroma analyses, the SQ-Zeta is the ultimate general-purpose GC-MS with high-performance capabilities for a wide variety of measurement and analysis needs.
JMS-Q1600GC GCMS
  • ∎ Features

    High sensitivity and Excellent dynamic range

    • IDL < 5 fg
    Eight sequential measurements of 20 fg of octafluoronaphthalene (OFN) were performed by using the standard EI ion source. The instrument detection limit (IDL) is calculated based on the peak area and reproducibility of the extracted ion chromatogram for the molecular ion. An IDL of 2.6 fg was achieved for the system.
     
    High sensitivity and Excellent dynamic range

    Wide dynamic range

    OFN at concentrations ranging from 0.005 to 1,000 pg / uL were measured by using SIM mode with the standard EI ion source. A calibration curve with good linearity was obtained with a coefficient of determination of 0.999 or better. A wide dynamic range of more than 5 orders of magnitude is useful not only for quantitative analysis, but also for qualitative analysis of complex mixtures with different concentrations.
     
    Wide dynamic range
    Two unique EI ion sources
    Expanded analytical solutions!
     

    Enhanced Performance Ion Source (EPIS, option) : IDL < 1 fg

    The EPIS offers the highest in-class sensitivity in the industry with an instrument detection limit of < 1 fg (OFN 5 fg, eight measurements). As a result, the EPIS offers a variety of benefits that include:
    • Trace-level quantitative analysis
    • Simplification of sample concentration analysis, reduction of sample introduction volume (contamination reduction)
    • Replacement of quantitative measurement method from SIM to SCAN (simplification of measurement condition, non-target analysis possible).
    The EPIS can be utilized not only for quantitative analysis but also qualitative analysis.
     

    Eight sequential measurements of 5 fg of octafluoronaphthalene (OFN) were performed by using the EPIS ion source.
    The instrument detection limit (IDL) is calculated based on the peak area and reproducibility of the extracted ion chromatogram for the molecular ion. An IDL of 0.6 fg was achieved for the system.
    • Photoionization EI/PI Combination Ion Source (option)
    Photoionization (PI) is a soft ionization method that uses a vacuum ultraviolet (VUV) lamp. The EI/PI combination ion source allows both EI (Hard ionization) and PI (Soft ionization) without removing the ion source. All that is required for switching between EI and PI is to turn OFF the EI filament and turn ON the PI lamp or vice versa.
    • No need to replace the ion source
    • No need to break vacuum
    • No need for reagent gases
    • Primarily for qualitative analysis
     
    Schematic of EI-PI Combination Ion Source 0209-06
    EI/PI

    Py/GC-MS measurement result of polystyrene foam

    Aromatic hydrocarbons, which strongly absorb UV light, are preferentially ionized by PI, resulting in high sensitivity detection of their molecular ions.
     

    Full range of software

    • Integrated qualitative analysis software "msFineAnalysis iQ"
    Break free from qualitative analysis based on library search alone! A higher level of qualitative analysis is possible by combining EI and soft ionization data! Based on our highly acclaimed msFineAnalysis software for GC-TOFMS, the new msFineAnalysis iQ expands this integrated qualitative analysis capability into GC-QMS data analysis.
    This software automatically combines the library search results from the EI data with molecular ion information from the soft ionization data, and then reports the results in a color coded table. This combination of EI and soft ionization results in improved accuracy for identifying unknowns when compared to relying on library database searches alone.

    Integrated qualitative analysis software "msFineAnalysis iQ"


    msFineAnalysis iQ automatically performs the following steps.

    1. Peak detection (deconvolution peak or TIC peak detection)
    2. Link of EI and SI data (link)
    3. Library search (EI)
    4. Molecular ion search (SI)
    5. Libray search result (EI, SI integration)
    6. Integrated analysis result
    Using EI and SI in combination with msFineAnalysis iQ provides a higher level of qualitative analysis results than relying on database searches alone.
     
    Integrated Analysis Result Window Individual Analysis Window
    Integrated Analysis Result Window Individual Analysis Window

     
  •  
    Items Specification
    Mass range 1 to 1022 u
    EI mode  IDL IDL < 5 fg
    Analyzer High-precision hyperbolic quadrupole mass filter
    Plug-in prefilter system
    Detector Conversion dynode/ion multiplier detection
    Detection of positive/negative ion
    • Integrated Qualitative Analysis of Additive Components in Adhesive and Acrylic Resin Oligomers
    • Thermal-decomposition Process Analysis of organic compounds
    • Qualitative analysis of unknown substances
    • Competitive products analysis
    • Differential analysis for food
    • Rapid analysis of phthalates for RoHS 2.0
    • Polymeric materials analysis