Thermtest Instruments Transient Hot-Wire (THW-L2) Model:THW-L2
The Transient Hot-Wire (THW-L2) is a portable thermal conductivity meter for measurement of liquids.
Best For Liquids
Best For Liquids
-
The Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. The THW-L2 was designed with speed and operational simplicity in mind. With a single measurement of less than 2 seconds in duration, small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. The THW-L2 utilizes a non-stationary measurement approach and rapid test times to limit convective effects for samples with a wide range of viscosities.
∎ Features
The Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. The THW-L2 was designed with speed and operational simplicity in mind. With a single measurement of less than 2 seconds in duration, small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity.
The THW-L2 utilizes a non-stationary measurement approach and rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a thin heating wire 60 mm in length and is completely inserted into the sample to be tested.
The sensor wire is heated using a constant current source (q) and the temperature rise is recorded by monitoring the change in electrical resistance of the wire. The slope (m) from the plot of temperature rise vs. logarithm of time is used in the calculation of thermal conductivity, the higher the slope.
- Follows international standard: ASTM D7896-19
- Portable, economical and accurate
- Results without the effects of convection
- Easy to use
- Optional thermoelectric dry bath for automated temperature testing
-
Materials Liquids & Pastes Measurement Capabilities Bulk Properties Thermal Conductivity 0.01 to 2 W/m•K Measurement Time < 2 seconds Reproducibility Typically better than 2% Accuracy Typically better than 5% Temperature Range -50 to 100°C Pressure Ambient Smallest Volume 15 ml Largest Sample Size Unlimited Standards 100 mm: ASTM D5334-22a, and IEEE 442-1981;
150mm: ASTM D5334-22a, IEEE 442-1981, and IEEE 442-2017 -
- Thermal Conductivity of Solvents
- Thermal Conductivity of DIUF Water
- Thermal Conductivity and Viscosity of Carbon Black Heat Transfer Nanofluids
- Thermal Conductivity of Salty Water Mixtures