• 品質因細節而決定

Thermtest Instruments Transient Hot-Wire (THW-L2) Model:THW-L2

The Transient Hot-Wire (THW-L2) is a portable thermal conductivity meter for measurement of liquids.
Best For Liquids
TECHMAX_CN_PRODUCTS_Thermtest_THW-L2-_01
  • The Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. The THW-L2 was designed with speed and operational simplicity in mind. With a single measurement of less than 2 seconds in duration, small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. The THW-L2 utilizes a non-stationary measurement approach and rapid test times to limit convective effects for samples with a wide range of viscosities.

    ∎ Features

    The Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. The THW-L2 was designed with speed and operational simplicity in mind. With a single measurement of less than 2 seconds in duration, small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity.
    The THW-L2 utilizes a non-stationary measurement approach and rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a thin heating wire 60 mm in length and is completely inserted into the sample to be tested.
    The sensor wire is heated using a constant current source (q) and the temperature rise is recorded by monitoring the change in electrical resistance of the wire. The slope (m) from the plot of temperature rise vs. logarithm of time is used in the calculation of thermal conductivity, the higher the slope.
     
    THW-L2 analysis
    • Follows international standard: ASTM D7896-19
    • Portable, economical and accurate
    • Results without the effects of convection
    • Easy to use
    • Optional thermoelectric dry bath for automated temperature testing
  • Materials Liquids & Pastes
    Measurement Capabilities Bulk Properties
    Thermal Conductivity 0.01 to 2 W/m•K
    Measurement Time < 2 seconds
    Reproducibility Typically better than 2%
    Accuracy Typically better than 5%
    Temperature Range -50 to 100°C
    Pressure Ambient
    Smallest Volume 15 ml
    Largest Sample Size Unlimited
    Standards 100 mm: ASTM D5334-22a, and IEEE 442-1981;
    150mm: ASTM D5334-22a, IEEE 442-1981, and IEEE 442-2017
    • Thermal Conductivity of Solvents
    • Thermal Conductivity of DIUF Water
    • Thermal Conductivity and Viscosity of Carbon Black Heat Transfer Nanofluids
    • Thermal Conductivity of Salty Water Mixtures
COPYRIGHT © TECHMAX TECHNICAL CO.,LTD All Rights Reserved | Design By iBest