Thermtest Instruments Transient Line Source (TLS-100) Model:TLS-100
The TLS-100 is a portable meter used to measure thermal conductivity and thermal resistivity of a variety of samples, including soil, rocks, concrete, and polymers.
Best For Soil, Rock, Concrete, and Polymers
Best For Soil, Rock, Concrete, and Polymers
-
The Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. The THW-L2 was designed with speed and operational simplicity in mind. With a single measurement of less than 2 seconds in duration, small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. The THW-L2 utilizes a non-stationary measurement approach and rapid test times to limit convective effects for samples with a wide range of viscosities.
∎ Features
The TLS-100 is a portable meter used to measure thermal conductivity and thermal resistivity of a variety of samples, including soil, rocks, concrete and polymers. Tests can be performed with the push of a button and results are displayed instantly. The second generation TLS-100 has many advancements, such as sensors that are auto-recognized with corresponding testing parameters automatically loaded.
The TLS-100 follows ASTM D5334-22a and IEEE 442-2017. The sensor needle consists of a thin heating wire and temperature sensor sealed in a 150, 100 or 50 mm steel tube. The sensor is completely inserted into the sample to be tested. Heat is delivered to the sample using a constant current source (q) and the temperature rise is recorded over a defined period of time. The slope (a) from plot of temperature rise versus logarithm of time is used in the calculation of thermal conductivity (k). The higher the thermal conductivity of a sample, the lower the slope. For samples of low thermal conductivity, the slope will be higher
- Follows international standards: ASTM D5334-22a, & IEEE 442-2017
- Economical, smart and accurate
- Easy to use
- Standard 100 mm / 150 mm sensor for soft materials
- Standard 50 mm sensor for hard materials
-
Materials Soil, Rock, Concrete, & Polymers Measurement Capabilities Bulk Properties Thermal Conductivity 0.1 to 5 W/m•K Thermal Resistivity 0.2 to 10 m•K/W Measurement Time 3 minutes Reproducibility ± 2% Accuracy ± 5% Temperature Range -40 to 100°C Largest Sample Size Unlimited Standards 100 mm: ASTM D5334-22a, and IEEE 442-1981;
150mm: ASTM D5334-22a, IEEE 442-1981, and IEEE 442-2017 -
- Thermal Conductivity of Ceramics
- Thermal Conductivity of Soil
- Thermal Conductivity of Snow